Boston, MA - June 20-22, 2017

06/20/17

TRANSFORMER 360 (Earn 0.8 CEU, 8 PDH credits each day)

Half-Century Transformer: Re-Energized! (Day One)

This one-day review course takes a new and updated look at the latest standards and best practices in transformer reliability. It covers the fundamentals of transformer oil sampling, testing, analytics and diagnostics. This course provides a solid introduction to transformer maintenance and is also a good review for anyone previously trained.

06/20/17

Transformer 360

Half-Century Transformer: Re-Energized!
This one-day review course takes a new and updated look at the latest standards and best practices in transformer reliability. It covers the fundamentals of transformer oil sampling, testing, analytics and diagnostics. This course provides a solid introduction to transformer maintenance and is also a good review for anyone previously trained.

  • Transformer Basics
  • Solid Insulation
  • Liquid Insulation
  • Testing Insulating Liquids
  • Working with Test Data
  • Transformer Maintenance
  • Industry Developments

Credits: 0.8 CEU, 8 PDH / day

 

Risk and Reliability: Day Two AM
This segment provides the foundation for moving from a testing and maintenance strategy to a reliability strategy. It includes helpful information from the insurance industry and reliability best-practice tools.

  • From Maintenance to Reliability
  • Criticality Assessment
  • The Risk Priority Number Method
  • Failure Modes Effects Analysis
  • Reliability-Centered Maintenance

 

Dissolved Gas Analysis: Day Two PM
This segment is an intensive look at DGA, one of the primary tools for monitoring the health of your transformer. The emphasis is on the changing technology itself and on understanding and using the data generated to make wise, practical decisions.

  • The Rationale for DGA
  • The Sources of Gas in Transformers
  • Interpreting the Presence of Gas
  • DGA Monitors
  • DGA Results Activity

Credits: 0.8 CEU, 8 PDH / day 

 

Load Tap Changers: Day Three AM
This segment underscores the oft-neglected importance of testing and maintaining LTCs. Our experience has shown that many otherwise well-trained professionals benefit greatly from this training module.

  • Overview of Voltage Regulation
  • The First Rule of Load Tap Changing
  • LTC Theory
  • Review of Components
  • Types of LTCs
  • Oil Aging in LTCs
  • Preventive Maintenance
  • Routine Monitoring and Testing

 

Electrical Testing: Day Three PM
This segment is dedicated to the important role of electrical testing in pursuit of an in-depth transformer condition assessment. The session also provides an examination of more advanced testing and maintenance strategies.

  • Power Factor Overview
  • Transformer Excitation Current
  • Transformer Turns Ratios
  • Four Types of Resistance
  • Swept Frequency Response Analysis
  • Case Studies

Credits: 0.8 CEU, 8 PDH / day

06/21/17

Risk & Reliability Fundamentals (Day Two AM)

This segment provides the foundation for moving from a testing and maintenance strategy to a reliability strategy. It includes helpful information from the insurance industry and reliability best-practice tools.

06/21/17

Dissolved Gas Analysis Fundamentals (Day Two PM)

This segment is an intensive look at DGA, one of the primary tools for monitoring the health of your transformer. The emphasis is on the changing technology itself and on understanding and using the data generated to make wise, practical decisions.

06/22/17

Load Tap Changer Fundamentals (Day Three AM)

This segment underscores the oft-neglected importance of testing and maintaining LTCs. Our experience has shown that many otherwise well-trained professionals benefit greatly from this training module.

06/22/17

Electrical Testing Fundamentals (Day Three PM)

This segment is dedicated to the important role of electrical testing in pursuit of an in-depth transformer condition assessment. The session also provides an examination of more advanced testing and maintenance strategies.

Register to Attend:

Transformer 360: Half-Century Transformer Re-Energized (Day 1)
06/20/17
$800
Transformer 360: Risk & Reliability/DGA (Day 2)
06/21/17
$800
Transformer 360: LTC/Electrical Testing (Day 3)
06/22/17
$800
BUNDLED Courses HCT Re-Energized, Risk & Reliability/DGA (Days 1 & 2)
06/20/17-06/21/17
$1300
BUNDLED Courses Risk & Reliability/DGA and LTC/ET (Days 2 & 3)
06/21/17-06/22/17
$1300
BUNDLED Courses HCT Re-Energized, LTC/ET (Days 1 & 3)
06/20/17 & 06/22/17
$1300
HCT, Risk & Reliability/DGA and LTC/ET (Days 1-3)
06/20/17-06/22/17
$1600
Please wait while logging in.