Principles of Transformer Maintenance (Online)

Purchase individual online courses or purchase all courses as a bundle for the complete online program.

ENTIRE COURSE: PRINCIPLES OF TRANSFORMER MAINTENANCE ONLINE BUNDLE

Includes all 13 courses above.  CEU's (credits):  1.3 CEU’s, 13 PDH’s

$399.00 USD

To create a new account or to continue learning with an existing account, log in to our Online Training Center:

Get Started or Continue

or call 330.630.7000 x3007 to register by phone.


INDIVIDUAL COURSES:


INTRODUCTION TO ELECTRICAL CONCEPTS (Module 0) ::  $39.00

This course discusses the fundamental theory of electricity, origin of electricity, components of electricity, how it is generated and transmitted, and the fundamentals of how a transformer works to transform electricity. (22 minutes)

Course Outline:

  • AC Generation and Induction
  • Transforming AC Power by Induction
  • Induction and Turns Ratio
  • Generation, Transmission, Distribution
  • Development of the Modern AC Transformer for Transmission and Distribution

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

INTRODUCTION TO TRANSFORMER DESIGN AND CONSTRUCTION (Module 1)  ::  $39.00

This course describes fundamental designs and construction of the internals of the transformer including core and coils. This basic information is vital to understanding how to effectively maintain a transformer in order to maximize effective operating life. (19 minutes)

Course Outline:

  • Core Steel and Core Configuration
  • Conductors and Windings / Coils

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

SOLID INSULATION (Module 2)  ::  $39.00

This course describes the mechanical forces that are generated in transformers, the multiple forms of solid insulation that can be found inside the transformer and specifically addresses the functions, strengths and enemies within your control of the most common solid insulation, which is cellulose paper. (40 minutes)

Course Outline:

  • Mechanical Forces
  • Kraft Paper
  • Insulation Aging and Mechanical Strengths

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

TRANSFORMER OIL (Module 3)  ::  $39.00

This course will explain the functions of insulating oil, what accelerates the aging process, the damage that can be caused by improper maintenance and the benefits of preventive maintenance to the life of the transformer. (17 minutes)

Course Outline:

  • Four Functions of Oil
  • Oil Aging Process (Oxidation)
  • How oil Aging and Oxidation Affect the Four Functions
  • What speeds up the process?  Can we control it?

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

INTRODUCTION TO OIL TESTING (Module 4)  ::  $39.00

This course will discuss the transformer failure modes and will introduce some of the different liquid insulation tests that can be done to monitor the transformer failure modes. (27 minutes)

Course Outline:

  • Failure Modes
  • When and why do we test transformer oil?
  • What tests do we run?

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

IN-SERVICE ROUTINE OIL TESTING (Module 5)  ::  $39.00

We use dielectric fluid testing as a means to determine condition and operation of the transformer in order to maximize its life. It is important to understand what tests are run, how results are generated and how to interpret those results. This course provides that required base knowledge. (25 minutes)

Course Outline:

  • Liquid Screen Tests
  • Liquid Power Factor
  • Oxidation Inhibitor Content

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

MOISTURE IN TRANSFORMERS (Module 6)  ::  $39.00

This course provides detailed information for the understanding and maintenance of moisture in transformers. It includes parts per million, percent saturation, percent moisture by dry weight, and the method to utilize this information to extend the reliable and cost effective life of the transformer. (49 minutes)

Course Outline:

  • Basic Issues
  • Saturation of Moisture in the Oil
  • Moisture in the Paper

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

DISSOLVED GAS ANALYSIS (Module 7)  ::  $39.00

This course gives the individual the ability to take dissolved gas analysis readings provided by routine oil testing and better understand what is happening on the inside of the transformer We look at the four key combustible gases and what those gases represent, in order to determine severity, materials involved and required action to prevent failure or permanent damage. (43 minutes)

Course Outline:

  • Basic Issues
  • What do the gases mean?
  • Key Gas Analysis
  • C57.104 (2008) “IEEE Gas Guide”
  • Key Gas Analysis – example
  • Some Final DGA Issues

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

FURANS AND NON-ROUTINE OIL TESTS (Module 8)  ::  $39.00

From calculating the remaining life of the solid insulation in your transformer with Furan analysis, to investigating problem test results such as Particle Count and Corrosive Sulfur. This course will explain critical, recommended and investigative testing and analysis of energized transformers that are available to you as you manage this critical asset. (45 minutes)

Course Outline:

  • Analysis of Furanic Compounds
  • Dissolved Metals Analysis, PCB Content, Particle Analysis, and Corrosive Sulfur

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

ELECTRICAL TESTING PRINCIPLES (Module 9)  ::  $39.00

Factory, acceptance, and field electrical testing will provide you with valuable information about your transformers condition. The factory tests will verify that the unit was built to the proper specifications.  The acceptance tests will help determine if the unit sustained any damage in transit to the site, and provide a benchmark for future field testing.  Field electrical tests are performed routinely to indicate if the insulation system is showing any signs of deterioration.  Also, it is recommended that the unit be tested after a fault to indicate if the unit suffered any damage.  This course will familiarize you with the testing required. (41 minutes)

Course Outline:

  • Factory Electrical testing
  • Acceptance Electrical Testing
  • Routine and Diagnostic Field Electrical Testing

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

INTERPRETING OIL TEST RESULTS (Module 10)  ::  $39.00

This course explains and shows the permanent damage to insulating paper caused by oil degradation, and therefore, the need for an overall oil testing program to understand the condition of the transformer. Building from the test result data, we will then explain the oil test result classifications and recommendations leading to the proper predictive and preventive maintenance services to extend the reliable and cost effective life of the transformer. (35 minutes)

Course Outline:

  • Oil and Paper Aging
  • Criteria for Interpreting Oil Test Analysis
  • Review of Moisture Criteria

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

MAINTENANCE OPTIONS (Module 11)  ::  $39.00

This course discusses what the options are when test results indicate questionable or unacceptable ranges. Also discussed are the differences between each maintenance option such as reconditioning and dehydrating oil maintenance for aging oil and the solid insulation. (28 minutes)

Course Outline:

  • Reconditioning Oil
  • Drying Transformers
  • Oil Maintenance for Aging Oil and insulation

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue

MAINTENANCE PROGRAM REVIEW (Module 12)  ::  $39.00

This course discusses the difference maintenance practices, our MaxLife philosophy and sludge-free operation.  Also discussed is important information about the life of the transformer and how to maximize the life of your transformer. (21 minutes)

Course Outline:

  • Putting Together Your Maintenance Program
  • Things to Remember

To purchase a module or to continue learning with an existing account, log in to our Online Training Center:

Buy or Continue



ENTIRE COURSE: PRINCIPLES OF TRANSFORMER MAINTENANCE ONLINE BUNDLE

Includes all 13 courses above.  CEU's (credits):  1.3 CEU’s, 13 PDH’s

$399.00 USD

To create a new account or to continue learning with an existing account, log in to our Online Training Center:

Get Started or Continue

or call 330.630.7000 x3007 to register by phone.

Please wait while logging in.