Transformer Maintenance Seminars

Focused learning at an affordable rate and at convenient locations.

SD Myers, Inc. offers a variety of courses designed to bring about the benefit, competence, confidence, reliability and power to transform both the individuals and the organization. Find the training that’s best suited for you, or we can customize a unique program for your organization.

Electrical Testing - Power Factor Testing

This is a 1-day class that gives an in depth understanding of Power Factor Testing in the field. The Power Factor is a measurement of the efficiency of the transformer's insulation system and therefore a reliable electrical test to detect deterioration that may cause significant issues with the operation of the transformer.

Learn More

Transformer Management Essentials

This course provides a foundational understanding of the internal and external elements of the transformer, the essentials of transformer operation and maintenance implementation and related industry standards. It covers the chemical, mechanical and electrical components of the transformer, the purpose and operating characteristics of these components, the significant requirements and methods for maintenance, and the major testing involved in maintenance.

Learn More

Principios de Mantenimiento de Transformadores

Este curso introduce al alumno en una serie de temas que resumen los fundamentos básicos de los transformadores y de mantenimiento del transformador.

Learn More

Fundamentos de Gestión de Transformadores

Este curso proporciona una comprensión básica de los elementos internos y externos del transformador, lo esencial en la operación y en la ejecución de mantenimiento del transformador y las normas relacionadas de la industria. Abarca los componentes químicos, mecánicos y eléctricos del transformador, las características de uso y de operación de estos componentes, los requisitos y los métodos importantes para el mantenimiento, las pruebas y las más importantes pruebas que tienen que ver con mantenimiento.

Learn More

Hoover Dam - Principles of Transformer Maintenance with Hoover Dam Tour

This course introduces the student to a range of topics summarizing the basic fundamentals of transformers and transformer maintenance including basic electric concepts, introduction to transformers, solid and liquid insulation, oil testing and analysis, basic electrical testing, and maintenance.

Also included in this course is a VIP tour of the Hoover Dam! See, learn and appreciate what it's all about.  The Hoover Dam has been rated by the American Society of Civil Engineers as one of "America's Seven Modern Civil Engineering Wonders". The 10-acre facility houses 17 generators and produces more than four billion kilowatt hours of electricity in a year.

Highlights of the VIP tour include views of:

 - Inside the power plant
 - 17 hydroelectric generators
 - 30-foot-diameter pipes (transports nearly 90,000 gallons of water per second)
 - Dam construction complexities
 - Inspection tunnels
 - Lake Mead, Colorado Rive, Nevada and Arizona Spillways
 - Nevada Intake Towers
 - Maps, photos and displays

Learn More

Principles of Transformer Maintenance

This course introduces the student to a range of topics summarizing the basic fundamentals of transformers and transformer maintenance including basic electric concepts, introduction to transformers, solid and liquid insulation, oil testing and analysis, basic electrical testing, and maintenance. Students can bring their own transformer oil test data to use as a class case study and/or get personalized assistance from an instructor.

Learn More

Load Tap Changer Principles and Maintenance (LTC)

This class explains the theory of load tap changing and identifies the various types and styles of tap changers, their components, and sequences of operation. Additionally, this class discusses monitoring, inspections, and testing required for developing an intelligent preventative load tap changer (LTC) maintenance program.

Learn More

Electrical Testing - Power Factor Testing (hands-on)

Learn More

Reliability Plan for Transformers

This class will allow you to properly assess the condition of the transformer by developing analysis tools and processes and applying these tools and processes toward establishing and implementing a reliability plan to maintain continuous up-time.

Learn More

Advanced DGA Diagnostics

Learn to identify fault gases and what causes their formation. We will explain and provide examples of qualitative and quantitative interpretation of dissolved gases and how to evaluate the condition of cellulose insulation. This class will also examine the role DGA plays in new oil testing and discuss procedures to obtain a representative sample from transformers.

Learn More

Hoover Dam - Transformer Management Essentials with Hoover Dam Tour

This course provides a foundational understanding of the internal and external elements of the transformer, the essentials of transformer operation and maintenance implementation and related industry standards. It covers the chemical, mechanical and electrical components of the transformer, the purpose and operating characteristics of these components, the significant requirements and methods for maintenance, and the major testing involved in maintenance.


Also included in this course is a VIP tour of the Hoover Dam! See, learn and appreciate what it's all about.  The Hoover Dam has been rated by the American Society of Civil Engineers as one of "America's Seven Modern Civil Engineering Wonders". The 10-acre facility houses 17 generators and produces more than four billion kilowatt hours of electricity in a year.

Highlights of the VIP tour include views of:

 - Inside the power plant
 - 17 hydroelectric generators
 - 30-foot-diameter pipes (transports nearly 90,000 gallons of water per second)
 - Dam construction complexities
 - Inspection tunnels
 - Lake Mead, Colorado Rive, Nevada and Arizona Spillways
 - Nevada Intake Towers
 - Maps, photos and displays

Learn More

Inspection & Sampling

Learn the proper and safe procedures needed to obtain a representative sample of dielectric fluid. Features a sampling demonstration and practical exercises to obtain accurate oils samples for use in lab analysis.

Learn More

Transformer Management Essentials Re-Energized

This one-day review course takes a new and updated look at the latest standards and best practices in transformer reliability. It covers the fundamentals of transformer oil sampling, testing, analytics and diagnostics. This course provides a solid introduction to transformer maintenance and is also a good review for anyone previously trained.

Learn More

Risk Assessment & Asset Management

This seminar will provide training and education to those responsible for identifying, assessing and mitigating risks associated with distribution and power transformers.

Learn More

Practical Application

The Practical Application class is a one-day workshop that is heavily focused on applying the classroom concepts to practical use on the job.  This class is primarily intended for those students who have more extensive needs for operating independently within their companies’ electrical equipment maintenance programs.

Learn More

Risk and Reliability Fundamentals

This segment provides the foundation for moving from a testing and maintenance strategy to a reliability strategy. It includes helpful information from the insurance industry and reliability best-practice tools.

Learn More

Dissolved Gas Analysis Fundamentals (DGA)

This segment is an intensive look at DGA, one of the primary tools for monitoring the health of your transformer. The emphasis is on the changing technology itself and on understanding and using the data generated to make wise, practical decisions.

Learn More

Load Tap Changer Fundamentals (LTC)

This segment underscores the oft-neglected importance of testing and maintaining LTCs. Our experience has shown that many otherwise well-trained professionals benefit greatly from this training module.

Learn More

Electrical Testing Fundamentals

This segment is dedicated to the important role of electrical testing in pursuit of an in-depth transformer condition assessment. The session also provides an examination of more advanced testing and maintenance strategies.

Learn More

Advanced Transformer Management

The aging of existing transformers and the changes in modern transformer design are two of the challenges currently facing maintenance professionals. The Advanced Transformer Management Course was developed to help equip the next generation of professionals to competently meet those challenges. Configured for flexibility, this course is divided into three one-day segments that may be taken as a whole or separated according to individual need.

Learn More

Transformer Management Essentials - Spanish

This course provides a foundational understanding of the internal and external elements of the transformer, the essentials of transformer operation and maintenance implementation and related industry standards. It covers the chemical, mechanical and electrical components of the transformer, the purpose and operating characteristics of these components, the significant requirements and methods for maintenance, and the major testing involved in maintenance.

Learn More

Inspección y Muestreo de Transformadores

En este curso le enseñará los procedimientos adecuados y seguros necesarios para obtener una muestra representativa del fluido dieléctrico.

Learn More

LatAm 360 - Spanish

El envejecimiento de los transformadores en servicios y los cambios en el diseño de transformadores modernos son dos de los desafíos que enfrentan actualmente los profesionales de mantenimiento. El curso Transformer 360 fue desarrollado para ayudar a equipar a la próxima generación de profesionales para enfrentar estos retos de manera competente. Configurado para la flexibilidad, este curso se divide en tres segmentos de un día que se pueden tomar como un todo o separados depende de la necesidad individual.

Learn More

These seminars are offered both at scheduled locations throughout the country or can be presented at your organization’s facility.

Enhanced Learning Series

Take your learning experience to the next level with the new enhanced learning courses available only at our Tallmadge, OH corporate headquarters.

 

Please wait while logging in.