On-Site

SDMyers offers all of the same transformer maintenance courses delivered on-site at your own company location.

On-site training at your facility provides several key benefits to you and your company:

  • Save your company substantial costs for attendee travel expenses, including airfare, hotels, and meals.
  • Save time by reducing your time away from the business.
  • Maintain peace of mind knowing that you are in the building should unexpected maintenance emergencies arise.
  • Standardize maintenance procedures by providing consistency in training for all your employees within the organization.
  • On-site training is available for as many employees as you need, just provide the space and the seating and we’ll do the rest.
  • Our seminars are available internationally and have been presented all over the world for various clients, in some cases with real-time translation.

Call 330.630.7000 x. 3485 or email traci.hopkins@sdmyers.com for more information about on-site training at your location.

Courses


Principles of Transformer Maintenance

This course introduces the student to a range of topics summarizing the fundamentals of transformers and transformer maintenance including basic electric concepts, introduction to transformers, solid and liquid insulation, oil testing and analysis, basic electrical testing, and maintenance. 

Inspection & Sampling of Fluid-Filled Transformers

Learn the proper and safe procedures needed to obtain a representative sample of dielectric fluid. Features a sampling demonstration and practical exercises to obtain accurate oils samples for use in lab analysis.

Transformador 360: Spanish

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Donec id vulputate enim, sed pellentesque leo. Donec pulvinar massa quis enim ornare, nec dapibus diam ornare. Praesent vel augue sit amet nisi egestas accumsan. Quisque sed justo et ex lobortis sodales. Nunc tristique accumsan ligula, et feugiat purus dignissim at. 

Principios de Mantenimiento de Transformadores

Este curso introduce al alumno en una serie de temas que resumen los fundamentos básicos de los transformadores y de mantenimiento del transformador.

Transformer Management Essentials

This course provides a foundational understanding of the internal and external elements of the transformer, the essentials of transformer operation and maintenance implementation and related industry standards.

Load Tap Changer Principles & Maintenance

This class explains the theory of load tap changing and identifies the various types and styles of tap changers, their components, and sequences of operation. Additionally, this class discusses monitoring, inspections, and testing required for developing an intelligent preventative load tap changer (LTC) maintenance program.

Advanced DGA Diagnostics

Learn to identify fault gases and what causes their formation. We will explain and provide examples of qualitative and quantitative interpretation of dissolved gases and how to evaluate the condition of cellulose insulation.

Electrical & Power Factor Testing

This is a one-day class that gives an in depth understanding of Power Factor Testing in the field. The Power Factor is a measurement of the efficiency of the transformer's insulation system and therefore a reliable electrical test to detect deterioration that may cause significant issues with the operation of the transformer.

Advanced Transformer Management (formerly Transformer 360)

The aging of existing transformers and the changes in modern transformer design are two of the challenges currently facing maintenance professionals. The Advanced Transformer Management Course was developed to help equip the next generation of professionals to competently meet those challenges.

Inspección y Muestreo de Transformadores

En este curso le enseñará los procedimientos adecuados y seguros necesarios para obtener una muestra representativa del fluido dieléctrico.

El Transformador de Medio Siglo

This course provides a foundational understanding of the internal and external elements of the transformer, the essentials of transformer operation and maintenance implementation and related industry standards. 

Risk and Reliability Fundamentals

This segment provides the foundation for moving from a testing and maintenance strategy to a reliability strategy. It includes helpful information from the insurance industry and reliability best-practice tools.

Get in Touch Contact Us Contact us to learn more about on-site training at your location. Call Today: (330) 630 7000 Contact Us