SAFETY SOLUTIONS FOR ELECTRICAL EQUIPMENT
Safety doesn’t happen by accident. It happens by design.
The majority of the equipment that keeps industrial America running is overbuilt and aging yet extremely capable. You don’t need to replace what’s not broken. SDMyers can help you make modifications that comply with modern expectations. Our Safety First approach has led to a variety of safety innovations you can implement to remove the risks and protect your people.

SAMPLESAFE®
SampleSafe® for safer cabinet transformer sampling
The safest way to obtain oil samples from cabinet transformers—without deenergizing.
Technicians use SampleSafe® to obtain oil samples from cabinet transformers without deenergizing. SampleSafe® relocates the sampling point away from the most hazardous area of the transformer. With no need to open the cabinet door and with the technician away from the front of the equipment, SampleSafe® substitutes the risk of a potential arc flash incidents entirely during energized sampling. No more PPE. No more deenergizing.
- Relocates the hazard and keeps personnel out of harm’s way
- Eliminates PPE requirements that can slow down the energized sampling process
- Increases productivity by removing the need for additional PPE

IR WINDOWS
Precise and consistent IR thermography inspections… without the risk
Arc flash incidents happen when cabinet transformer doors open. Keep them closed.
Inspection windows substitute potentially hazardous aspects of vital maintenance tasks, such as infrared scanning. With inspection windows installed, technicians no longer need to fulfill stringent and time-consuming PPE requirements when taking infrared readings of high voltage equipment. With a tight-but-ample field of view, inspection.

Remote Transformer monitoring
Discover faults early to prevent hazards from developing
Keep an expert eye on your equipment 24/7 without setting foot in your substation.
Our transformer monitors work around the clock to provide you data that is accurate beyond industry standards. If we find an imminent threat to your system, we will contact you immediately with clear options on what to do next. Substations are hazardous enough. Armed with detailed data and insight from SDMyers, you’ll know what steps to take to keep your electrical system running—with fewer people inside the substation.
- Provides early warnings of conditions that could endanger the next person to enter the substation
- Increases your testing frequency exponentially so you always have access to relevant data
- Reduces substation foot traffic and lowers the hours your people spend next to high voltage equipment.