Transformer Management 1
The Foundations You Need to Become a Transformer Expert Everyone Relies On
Transformer Management 1 (TM1) is intended to lay a strong foundation for those who are in any way responsible for transformer maintenance. Students will gain a basic understanding of transformers, oil and electrical tests, maintenance principles, and the importance of a reliable electrical power system.
Credits you will earn: 2.05 CEU | 20.5 PDH | 20 NETA CTD
What you’ll learn
Transformer Management 1 (TM1) offers a series of nine courses that will lay a solid foundation for those who are responsible for transformer maintenance.
Transformer management from a reliability perspective
Chemical and electrical tests
Industry standards and their application
Transformer maintenance solutions
What's included
- Live online or in-person format
- Real-world case studies and discussion
- Industry credits (2.05 CEU/20.5 PDH/20 NETA CTD)
- Access to course recordings for 12 months
- Copy of Transformer Maintenance Guide, 3rd edition
- Transformer moisture calculator
Course Content
- Introduction to Reliability Centered Maintenance
This course is designed to create awareness of transformer management from a reliability perspective.
This course is a 2 hour course which earns .20 CEU / 2 PDH / 2 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Transformer Components and Functions
This course will identify transformer components and subcomponents. It will describe the functions of the components and the elements of design that affect maintenance including core configuration, winding type, conductor material, solid insulation type, cooling, and oil preservation.
This course is a 2 hour course which earns .20 CEU / 2 PDH / 2 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Solid Insulation Life and Aging
This class will cover the importance of the solid insulation in transformers. Attendees will take an in-depth look into the mechanical strength of the paper , and will understand that maintaining mechanical strength of the solid insulation is critical to extending the life of the transformer.
This course is a 2 hour course which earns .20 CEU / 2 PDH / 2 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Insulating Liquids
This course will cover the four functions of insulating liquids in transformers. It will identify the aging mechanism of mineral oil, understand the use of inhibitor, and cover the application of alternate fluids.
This is a 2.5 hour course which earns .25 CEU/2.5 PDH / 2.5 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Oil Tests and Interpretation
This course will cover sampling and inspection practices for fluid filled transformers. It will cover routine and non-routine tests that can be performed and will identify industry standards for these tests.
This course is a 2.5 hour course which earns .25 CEU / 2.5 PDH / 2.5 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Moisture in Transformers
This course will address the problems created by moisture in transformers. It will cover percent saturation, percent moisture by dry weight, and why those responsible for transformer maintenance need to understand the importance of managing moisture in their transformer fleet.
This course is a 2-hour course which earns .20 CEU / 2 PDH / 2 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Dissolved Gas Analysis (DGA) & Furans
This course will cover the scope of DGA and the formation and sources of dissolved gases in mineral oil immersed transformers. It will review the interpretation tools and guidance of the IEEE standards. It will cover how to identify furan content and how to understand furan testing.
This course is a 2.5 -hour course which earns .25 CEU / 2.5 PDH / 2.5 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Electrical Testing
This course will cover the various field electrical tests performed. It will cover a description of the test, the purpose of each test, and how to interpret the results. This class includes several case studies for real-world examples.
This course is a 2.5-hour course which earns .25 CEU / 25 PDH / 2.5 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
- Applied Transformer Maintenance
This course will cover the importance of extending the reliable life of the transformer by mechanical maintenance, electrical maintenance, and fluid maintenance. It will cover the corrective processes used in extending the life of the insulation system of the transformer. It will compare/contrast these oil processes and their performances.
This course is a 2 1/2 -hour course which earns .25 CEU / 2.5 PDH / 2.5 NETA CTD
Purchase the Learning Plan "Transformer Management 1" to take all 9 individual courses that make up that entire course. The 9 that are included are: Introduction to Reliability Centered Maintenance / Transformer Components & Functions / Solid insulation Life & Aging / Insulating Liquids / Oil Tests & Interpretation / Moisture in Transformers / DGA & Furans / Electrical Testing / Applied Transformer Maintenance. Purchasing as the Learning Plan saves $200!
TM1 is the first step in obtaining the Master Transformer Maintenance Professional Certification awarded by SDMyers. The Live Online version of TM1 is equivalent to the Traditional Classroom version of TM1 and is therefore accepted toward the professional certificate program. More information regarding the Certifications available from SDMyers can be found in the file repository section of this course.
This learning plan is for you if
your job requires basic understanding of:
Transformers
Oil & Electrical Tests
Maintenance Principles
The Importance of a Reliable Electrical Power System
Meet the Instructor

ARISMENDIS PEÑA, CRL
Aris Peña is the Program Manager and Lead Instructor with PowerPro360. Beginning his career as an International Business Development Representative, he has over 15 years of experience with power transformers. In addition to instructing, Aris plays an integral part in the technical development and design of all PowerPro360 training curriculum. He is an active member of IEEE, ASTM, CIGRE, SMRP, and the Association of Asset Management Professionals and is a Certified Reliability Leader (CRL).