IR Windows
IR Thermography Inspection Windows for Medium and High Voltage Equipment
Inspecting electrical substations can be dangerous. Even non-contact inspection methods, such as infrared thermography, pose risks to technicians. Arc flashes can happen when transformer doors or breaker and switchgear panels are opened, and injuries sustained from the burns and the percussive injuries that happen as a result of an arc flash can be life-changing — even deadly. IR inspection windows eliminate the need for thermographers to open energized equipment, greatly reducing the risk to personnel.
Quick Features List:
- IR window options that fit the way you work
- Do more in less time with IR windows
- The optimal safety product
- Precision installation by SDMyers
Models/Options
IR Window Models
- Rectangular Indoor IR Window 📄 Data Sheet
- Rectangular Outdoor IR Window 📄 Data Sheet
- Rectangular Outdoor IR Window w/PD Port 📄 Data Sheet
- Round Indoor/Outdoor IR Window 📄 Data Sheet
- Round Indoor/Outdoor PD Port 📄 Data Sheet
Features
01
DURABLE & RUGGED
Polymer-based IR windows are far more resistant to the mechanical stresses experienced on high-voltage electrical equipment.
02
ARC CONTAINMENT TESTED
Successfully tested to IEC 62271-200 for arc containment on metal enclosed switchgear assemblies.
03
UL LISTED
All IR windows from SDMyers have passed rigorous standards and testing, and are UL Listed (E491496).
04
ENVIRONMENTALLY SEALED DESIGNS
An additional layer of protection for both the inspection port and the equipment in harsher environments.
LARGE FIELD OF VIEW OPTION
For larger-size rectangular windows, we offer large field of view IR windows. These provide a clear view—compared to some opaque windows and others that are only offered in smaller, round sizes—for superior visual inspections.
AMERICAN MADE, GLOBALLY TRUSTED
100% conceived, designed, and built on American soil, embodying the innovation and quality of American manufacturing.
Specifications
IR Window Certifications and Specifications
View product download sections for individual IR window specification sheets.
- UL Listed (E491496)
- UL (USA) and cUL (Canada) to the following standards: 50V, 50E, 756C: Impact and Flammability, 746C & 746A-2012, 1558: Impact and Load Resistance, 508A: ANSI 508A
- CSA C22.2 No. 14-13, C22.2 No 14-10, C22.2 No. 94-M91, C22.2 No. 94.1-07, C22.2 No 94.2-07
- Lloyds of London Type Approval
- American Bureau of Shipping (ABS)
- DNV (Det Norske Veritas) P261.1E Maritime, Vessel and Offshore Applications
- IEEE C37 20.7 Type 2B, C37 20.2.a.3.6: Impact and Load
- IEC 62271-200, 60262271-200, 60298 Appendix A, 60068-2-6:2007, 60068-2-3, 60068-2-78:2012