SampleSafe® External Sampling Devices
The safest way to obtain liquid samples from cabinet transformers.
The SampleSafe® ST (standard model) and SampleSafe® ST Dual (dual valve model) are external oil sampling devices with the protection of a secure steel enclosure. Arc-flash exposure is one of the biggest risks when sampling cabinet transformers. SampleSafe external sampling devices move sampling access outside the cabinet, allowing technicians to take oil samples and support oil analysis without de-energizing or opening the transformer door.
Quick Features List:
- Sample while energized (no shutdown needed)
- Sample hassle-free (no bulky PPE and no door opening)
- Sample safely (reduces shock/arc-flash exposure by sampling externally)
- Ability to top-off the nitrogen blanket via SampleSafe
Models
SampleSafe® ST
Overall enclosure dimensions: Width 10” | Height 12” | Depth 6”
SampleSafe ST (standard model) includes all parts required to install a bottom valve extension inside a protective, powder-coated steel enclosure on the exterior of the transformer. This kit also contains provisions to relocate the pressure/vacuum gauge to the interior of the enclosure and, if one exists, the pressure relief valve (PRV) or pull ring. A viewing window is also provided on the secondary side cabinet door to view the level and temperature gauges, and for visual inspection.
SampleSafe® ST Dual
Overall enclosure dimensions: Width 12” | Height 16” | Depth 8”
The SampleSafe ST Dual (dual model) includes all parts needed to install both bottom and top valve extensions, housed in a single powder-coated steel enclosure on the exterior of the transformer. This kit includes the same provisions and benefits as SampleSafe ST, along with the proper valve size and connections for services such as online oil processing, top-offs, retrofilling, and connection to an online dryer (SDMyers DryMax®).
Features
01
External access that keeps technicians away from energized hazards
- Sample oil without opening the cabinet door
- Sampling access stays outside the energized zone
- Extends the bottom sampling valve for safer access
02
Designed to support safer work practices
- De-energizing is best — but not always possible
- Supports a “substitution” approach by moving sampling outside the cabinet
- Aligns with NFPA 70E and 70B guidelines
03
Eliminate downtime and bulky PPE
- No shutdown required to take a sample
- Reduces the need for extra bulky Arc Flash PPE
- Faster, simpler workflow for routine liquid sampling
04
Ready for advanced maintenance options
- Dual valve supports oil processing readiness
- Dual valve supports online dryer readiness (DryMax® hookup)
- Ability to top-off the nitrogen blanket via SampleSafe