Field Services

Moisture Reduction

Protect Your Transformer's Lifespan Without a Day of Downtime

The life of the paper is the life of the transformer. Rather than risking permanent damage from moisture and oxidation leading to premature loss of equipment life, make moisture reduction a priority with SDMyers’ drying solutions.

Why moisture is your transformer's silent killer.

Moisture doesn’t just live in your transformer oil. It also lives in the paper insulation, where the real danger lies. The paper insulation provides the electrical insulation that keeps conductors safely separated. It also has to withstand the mechanical and electrical stresses a transformer experiences as it ages. As moisture degrades the paper, it grows brittle and loses that strength in ways that can’t be undone. 

The math is unforgiving: every time moisture content doubles, paper lifespan is cut in half. And every year you delay, you lose approximately two years of reliable service. Degraded paper insulation also dramatically increases your risk of flashover and dielectric failure. This kind of catastrophic event can take your operation offline without warning.

If one transformer is showing moisture alerts, the rest of your fleet is likely only a step behind.

Your Moisture Removal Options:

DryMax®

Online passive dehydration system that connects directly to a live transformer for as long as it takes to remove moisture from oil and paper insulation while it remains in service.

Field Dehydration

Uses heat and vacuum to remove moisture from the oil as it circulates through the unit.

Field Dry Out

Heat and direct vacuum are applied to the transformer tank after the unit is completely drained of fluid. Cold traps are used to collect and measure the drying process.

Factory Dry Out

The transformer is removed from service, drained, and transported to a transformer repair facility. Ovens, heat and vacuum equipment, and vapor phase drying are used to dry the transformer.

Specifications

DryMax®

Field Dehydration

Field Dry Out

Factory Dry Out

Dries the oil
Dries the paper
For non-vacuum-rated transformers
For vacuum-rated transformers
Work is completed on-site
Transformer may be energized
Can be monitored remotely
Improves other oil qualities
Anticipated days out of service
0
1-2
7-14
42

Important note: Leak repairs should be addressed prior to proceeding with the chosen method of dehydration.

DryMax® - The Online Passive Dryer Solution

An online passive dryer is the most recommended field procedure to dry a transformer. Unlike traditional moisture-reduction methods that force you offline, DryMax® connects directly to your live transformer and runs for as long as needed to completely remove moisture from oil and paper insulation. From the moment of installation, it prevents further degradation of your paper insulation while actively restoring your transformer to optimal condition. 

The result: Extended transformer life, reduced failure risk, and zero disruption to your operations.

Choose Your DryMax® Deployment Strategy

Flexible programs designed to protect your entire fleet.

Service-Only Program

Best for: Multiple transformers with immediate moisture issues

  • Get remedial moisture reduction without long-term equipment investment
  • Ideal when you need to address several units quickly
  • Full SDMyers service and support included
  • No capital commitment required

Mobile Installation

Best for: Fleet-wide moisture management

  • One DryMax® unit services multiple transformers
  • Equipment moves across your fleet as needed
  • Addresses the full scope of your moisture challenges
  • Most cost-effective for multiple wet transformers

Permanent Installation

Best for: Critical transformers under extreme loads

  • One dedicated DryMax® unit per transformer
  • Installed for the lifetime of the equipment
  • Continuous protection for your most essential assets
  • Complete service package included

Equipment Redeployment

Best for: Existing DryMax® owners

  • Update your current unit with remote monitoring
  • Full service and reinstallation support
  • Maximize your existing investment

A Complete Fleet Protection Approach

01

Assessment & Planning

We evaluate your fleet's moisture levels and operating conditions to recommend the optimal combination of programs for your specific needs.

02

Installation & Connection

DryMax® units are connected to your energized transformers with minimal disruption. Service begins immediately.

03

Active Moisture Removal

DryMax® continuously processes oil, removing moisture from paper insulation while your equipment operates normally.

04

Monitoring & Adjustment

We track moisture PPM levels throughout the process, adjusting as needed until stable, acceptable levels are achieved.

Learn More About Our Capabilities

Moisture Reduction in Transformers

Moisture in transformer dielectric fluid is a major problem which can mean premature and/or sudden failure of the transformer. We’ll discuss solutions, including our own DryMax® online dryer solution.

How Do You Remove Moisture From a Transformer?

Bob Rasor, Director of Transformer Services at SDMyers, explores the damage done by moisture and the methods transformer owners use to get rid of it.

What Is The Best Way To Dry Out a Wet Transformer?

Bob Rasor explains the three basic ways to dry a transformer: package it up and send it to a winding facility, perform a vacuum dryout in the field, or use an online dryer, like DryMax®.

How Can You Tell If a Transformer Is Wet?

There are a couple different ways to determine if a transformer is wet. When a fluid sample is analyzed alongside other data, it is possible to calculate the percent saturation — the water in the fluid at different temperatures.

Introducing InsulMax®

Need to tackle acids too? InsulMax® works like DryMax® but removes both moisture and acids from your oil while you stay energized.

Why Partner with SDMyers?

60+ years of transformer maintenance expertise.

Partner with reliability experts who understand that transformer moisture is rarely an isolated problem.

Fleet-wide thinking.

We help you protect all your equipment, not just today's problem.

Energized solutions.

Keep operating while we restore your assets.

Tailored programs.

No one-size-fits-all — we design solutions for your operating reality.

ISO-certified quality.

Consistent service backed by industry-leading standards.

Ongoing support.

From installation through monitoring, we're your long-term partners.

Resources

We’re the transformer experts so you don’t have to be. Explore resources backed by 60+ years of end-to-end transformer care experience and diagnostics data.

Frequently Asked Questions

Transformer moisture reduction is the process of removing water from both the insulating oil and the paper insulation inside a transformer. This is critical because moisture accelerates insulation aging, reduces dielectric strength, and significantly increases the risk of failure.

Moisture causes irreversible damage to paper insulation — the most critical component of your transformer. As moisture levels rise, insulation strength drops and aging accelerates. In fact, every time moisture content doubles, the expected life of the insulation is cut in half.

Yes. Advanced online drying solutions like DryMax® are specifically designed to connect to energized transformers and remove moisture continuously — without requiring downtime. This allows you to improve transformer health while maintaining normal operations.

DryMax® continuously circulates and processes transformer oil, removing moisture and creating conditions that draw water out of the paper insulation. Over time, this reduces total moisture content throughout the transformer system — not just in the oil.

The timeline depends on the transformer’s size, condition, and moisture levels. Moisture reduction is not an instant process — especially when removing water from solid insulation — but DryMax® begins protecting insulation immediately and continues improving conditions over time.

It can. Moisture may re-enter through seals, leaks, or ongoing insulation aging. That’s why continuous or long-term moisture management strategies are important for maintaining low levels over time.

You should act as soon as moisture is detected or trending upward. Early intervention prevents accelerated damage and helps avoid costly failures later.