• Services
  • Products
    • IR Windows

      Thermography inspection windows

    • SampleSafe

      External safe sampling devices

    • Guardian Monitoring

      Online DGA monitors

    • DryMax

      Transformer dry-out system

    • InsulMax

      Transformer oil purification system

  • Industries
    • Data Centers
    • Commercial & Industrial
    • Renewable Energy
    • Oil & Gas
    • Healthcare
    • Pulp & Paper
    • Utilities & Municipalities
    • Electrical Cooperatives
    • Petrochemical
  • Resources
    • Knowledge Center

      Expert articles, case studies, & guides

    • News

      Company news & announcements

    • Transformer Maintenance Guide

      Essential book for transformer owners

    • Training

      Maintenance & management training

    • Customer Resources

      Instructions & forms

  • Company
    • About Us

      Who we are

    • Our Approach

      Consulting & collaboration

    • Safety

      It's our culture

    • Acts 4:12

      Rooted in faith

    • Careers

      Join the team

Login
Contact
Services

Field Inspection

  • Visual Inspection
  • Field Sampling
  • Infrared Inspection
  • Partial Discharge Testing
  • Field Inspection Technicians (FITs)

Lab & Diagnostics

  • Oil Testing & Analysis
  • Oil Test Packages
  • Transformer Dashboard
  • Online Condition Monitoring

Field Services

  • Maintenance & Repair
  • Degassing & Vacuum Processing
  • Reinhibiting
  • Moisture Reduction
  • Hot Oil Cleaning
  • Retrofilling
  • Electrical Testing
  • Load Tap Changer Service

Fleet Reliability

  • Testing & Monitoring
  • Diagnosis & Assessment
  • Maintenance & Repair
  • Refurbish & Replace
Talk with a Transformer Expert
Products
  • IR Windows
  • SampleSafe
  • Guardian Monitoring
  • DryMax
  • InsulMax
Industries
  • Data Centers
  • Commercial & Industrial
  • Renewable Energy
  • Oil & Gas
  • Healthcare
  • Pulp & Paper
  • Utilities & Municipalities
  • Electrical Cooperatives
  • Petrochemical
Resources
  • Knowledge Center
  • News
  • Transformer Maintenance Guide
  • Training
  • Customer Resources
Company
  • About Us
  • Our Approach
  • Safety
  • Acts 4:12
  • Careers
Login

Welcome to the Knowledge Center

  • Diagnostic Testing
  • Insulating Liquids
  • Maintenance & Repair
  • Reliability
  • Safety
  • Knowledge Center
  • Articles
Articles

Dielectric Breakdown Voltage

How Are Dielectric Breakdown Voltage Tests Standardized? How D1816 Became the Standard for Dielectric Breakdown Testing How Do You Diagnose a Failed ASTM D1816 Result? How Do You Interpret ASTM D1816 Results Accurately? How Does ASTM D1816 Apply to New Insulating Oil?
See All

Furanic Compounds

How Are DP and Insulation Life Estimated from Furans Data? How Do Furanic Compounds Indicate Active Paper Degradation in Transformers? How Does Oil Processing Affect Furanic Compound Results? What Are Furanic Compounds and How Do They Form in Transformers? What Furanic Compound Levels Are Diagnostically Significant?
See All

Oil Sampling

How Do You Draw a Representative Transformer Oil Sample? What Information Do You Need Before Sampling Transformer Oil? Which Containers Should You Use for Transformer Oil Samples?

Transformer Reliability

How Do You Build a Transformer Preventive Maintenance Program That Actually Works? How Do You Plan for Transformer End-of-Life Before a Crisis Forces Your Hand? What Are the Risks of Transformer Failure — and How Are They Assessed?

Load Tap Changer

How Are Liquid Screen, Moisture, and DGA Used to Monitor LTCs? How Does Mineral Oil Age Inside a Load Tap Changer? How Is Particle Count Analysis Applied to Other Oil-Filled Equipment? What Can Analytical Ferrography Reveal About LTC Particle Sources? What Causes Accelerated Film Formation in LTCs?
See All

Moisture in Transformers

What Are the Methods for Drying a Wet Transformer? Where Does Transformer Moisture Come From? Why Is Drying Transformer Paper Insulation So Difficult?

FR3®

What Is FR3® Fluid and Why Is It Used in Transformers? Why Does FR3® Natural Ester Fluid Generate Ethane?

Corrosive Sulfur

How Is the Corrosive Sulfur Test Performed? What Is the Corrosive Sulfur Test for Transformer Oil? When Should the Corrosive Sulfur Test Be Performed?

AGE

How Is the AGE Test Performed and How Are Results Interpreted? What Is the AGE Additive and Which Transformers Require AGE Testing?

Liquid Power Factor

How Is Liquid Power Factor Used to Evaluate Transformer Oil? What Do Liquid Power Factor Test Values Indicate? When and How Should Liquid Power Factor Testing Be Applied?

PCBs

How Are PCB Regulations Applied to Electrical Equipment Classification? How Is PCB Content Tested in Dielectric Fluids and Solids?
Contact

Corporate Office

180 South Avenue
Tallmadge, OH 44278 USA

Contact Us

Get In Touch

Phone: (330) 630-7000
Email: info@sdmyers.com

My Dashboard
SDMyers

Services

  • Field Inspection

  • Lab & Diagnostics
  • Field Service
  • Products
  • Fleet Reliability

Resources

  • Knowledge Center
  • News
  • Transformer Maintenance Guide
  • Training
  • Customer Resources

Company

  • About
  • Acts 4:12
  • Careers
  • Safety
  • ISO Certification
  • Make a Payment

A Good Place Company™

Learn More

© Copyright 2026 SDMyers | 

Privacy Policy | Terms & Conditions | Cookie Policy | Consent Preferences | Site by Jolly Creative Agency