Dissolved Gas Analysis (DGA)

The Industry Standard for Transformer Fault Detection

Dissolved gas analysis (DGA) detects developing issues in your transformer long before they cause failures, outages, or costly emergency repairs. SDMyers delivers expert DGA testing backed by 60+ years of experience and one of the world's largest fluid testing databases.

What DGA Reveals and Why It Matters

When electrical or thermal faults occur inside a transformer, they generate specific gases that dissolve in the oil. Dissolved gas analysis identifies those gases — their type, concentration, and trend over time — to give you a precise picture of what's happening inside your equipment, often months before a fault becomes a failure.

Unplanned transformer failures don't just damage equipment. According to Aberdeen Research, they cost an average of $260,000 per hour in downtime, and 82% of companies experience unplanned outages within three years. DGA gives you the early warning you need to act on your schedule — not during an emergency.

4 Reasons to Perform DGA Testing:

Protect Your Assets

Catch developing faults early before they escalate

Maximize Uptime

Identify issues before they cause unplanned outages

Maintain Confidence

Replace guesswork with quantifiable, condition-based data

Peace of Mind

Trust that developing issues won't catch you off guard.

Expert Analysis Behind Every Sample

A reliable DGA assessment goes beyond measuring gas levels. Our specialists evaluate:

  • Gas concentrations — The type and quantity of gases present identify specific fault conditions inside your transformer.
  • Trends over time — Changes in gas levels between samples often reveal more than a single reading alone.
  • Transformer age and design — Older equipment and different transformer types have different baselines and tolerances.
  • Service history and environmental factors — Voltage stresses, load history, and operating environment all influence how results are interpreted.

How Our DGA Process Works

01

Inspect & Sample

Our Field Inspection Technicians (FITs) safely inspect and collect oil samples from energized transformers and ship them directly to our accredited lab for precise DGA testing.

02

Test & Analyze

Every sample is evaluated by trained transformer specialists using proven diagnostic methods and one of the world's largest transformer fluid testing databases.

03

Clear Recommendations

Results are delivered in plain language through your Transformer Dashboard®, with tailored recommendations ranging from increased monitoring to maintenance interventions — so you always know what to do next.

What the Gases in Your Oil Are Telling You

Electrical & Arcing Faults:
  • Acetylene: Indicates arcing, sparking, and severe overheating
  • Hydrogen: Accompanies most transformer faults and signals the need for deeper analysis
Thermal Faults:
  • Methane: Low-energy thermal faults
  • Ethane: Thermal faults starting around 250°C
  • Ethylene: Higher temperature faults (concentration increases with temperature)
Insulation Degradation:
  • Carbon Monoxide & Carbon Dioxide: Elevated levels indicate cellulose insulation breakdown
  • Oxygen & Nitrogen: Suggest air ingress, accelerating insulation degradation

Straight From Our Experts

DGA testing will give you information about what is actively going on today inside your transformer. It’s the industry standard for detecting faults and key gases in a transformer — and knowing how results change over time. It is a must-have for reliability.

— Jason Dennison | Director, Diagnostic Analytical Services